Atentions of Laboratory centrifuge using
1 The placing  centrifuge tube must be symmetrical placement!! In order to turn up, guarantee  unbiased, such as the four placed centrifuge tube position, must add two  centrifuge tubes and one put a
2 When opening the centrifuge to  centrifuge lid
3 When opening and closing the centrifuge must be slow  speed increase or decrease, can't make the speed of change  quickly
Another point is to ensure that the centrifugal tube symmetry,  but also to keep the weight.
The liquid is better not to be too low boiling  point, pay attention to internal and external pressure ratio.
If the  toxic reagent but also good ventilation treatment.
Medical,  pharmaceutical industry using a centrifuge to either non sterile environment or  aseptic environment, put forward very high requirements on the environment in  the using process, at a high level of environmental requirements, such as in the  aseptic workshop, there are million level, level one hundred thousand workshop,  good sealing performance can make the internal and external to keep the machine  effective isolation. Solid, liquid, gas centrifuge cavity phase shall not cross  contamination and operator, the external environment. In general, the use of  party in order to be informed of centrifuge manufacturers, the sealing  requirements. To improve the design of sealing performance to centrifuge  manufacturers, and fully embodied in the manufacturing, generally in the  following parts considered:
The lid seal: machine because is foldable,  and the casing joint surface should be a reliable seal measures, if because of  the sealing structure and material corrosion failure, it may cause the liquid,  gas leakage, damage to the environment, personnel.
Seal structure, seal  anti-corrosion performance, in the design and selection should take full account  of its sealing performance and reliable performance.
The mounting  interface feeding pipe, washing pipe, observation mirror and other additional  devices, there should be a reliable seal measures.
The seal bearing: for  the spindle nut, bearing seal, sealing measures in this respect the traditional  models of relatively simple, only the relative seal. Such as the spindle nut  position, the spindle nut and drum joint surface, generally do not set the seal  ring, the centrifuge in the operation process of the liquid phase, vapor  infiltration, corrosive to the spindle cone, even into the bearing, damage to  the bearing, thus affecting the normal use of the machine. On the bearing cap is  generally installed skeleton type seal structure, but on the bearing cap and a  part of the drum taper hole is exposed outside, centrifuge cavity in the gas  phase, it may bring the corrosion on the exposed surface of spindle. Centrifuge  used in pharmaceutical industry, the separation of the materials are organic  solvents or acid, alkali, salt and other media, so in the ordering of equipment  should consider these parts of the sealing requirements, set the seal or static  sealing structure, sealing requirements to achieve.
The sealing belt  area: traditional centrifuge the drive belt is open, just set up a protection on  the motor end cover, mainly from the security point of view, in order to improve  the safety, but for the pollution of the dust generated by the environment of  the friction is not to control, such as in clean areas is not feasible,  therefore, must be on the drive belt area closed up, to prevent the leakage of  friction dust.
The other part (a liquid outlet pipe, feeding pipe, a  hopper interface part): for the centrifuge external pipeline, such as feeding  pipe, washing pipe, tube, pipe cleaning, general selection of flange  installation, to ensure the sealing performance of the interface,
For  some very high cleanliness of the occasion, the interface should be used  sanitary quick open interface device, in order to facilitate cleaning.